Thiết bị giám sát phân tích hiệu suất - PM180
Model: PM180
Nhà sản xuất: SATEC
Xuất xứ: Isarel
SATEC eXpertMeterTM PM180 is a high performance analyzer that allows versatile uses. The high performance of the PM180, together with the unique flexible design of the expansion cards and the versatile installation on DIN rail, 4” round or 92x92mm cutout, enables its use in a large variety of applications, in which it can substitute several other devices—saving costs, space and complexity.
The unique modular design of the PM180 ensures its adaptation to changing needs, through a selection of numerous plug-in options for multiple customer applications. The PM180 can have up to 3 expansions modules. See Models & Accessories below.
Environmental Conditions | Operating Temperature: | -30°C to 70°C (-22°F to 158°F) |
Storage Temperature: | -40°C to 85°C (-40°F to 185°F) | |
Humidity: | 0 to 95% non-condensing | |
Altitude | ≤ 2000m | |
Construction | Overall Dimensions | |
Width: | 220.00 mm (8.66 Inches) | |
Height: | 152 mm (5.98 Inches) | |
Depth: | 210.00 mm (8.26 Inches) | |
Weight: | 2.5kg (5.51 Lb) | |
Materials | ||
Enclosure: | Polycarbonate | |
Panels: | Polycarbonate | |
PCB. : | FR4 (UL94-V0) | |
Terminals: | PBT (UL94-V0) | |
Connectors-Plug-in type: | Polyamide PA6.6 (UL94-V0) | |
Packaging Case: | Carton and Stratocell (Polyethylene Foam) Brackets | |
Labels: | Polyester film (UL94-V0) | |
Power Supply | Main Power Supply | |
Withstanding Insulation: | 4kV AC @ 1mn | |
AD/DC Power Supply (standard): | L/+, N/- and GND | |
Rated input: | 50-290VAC 50/60 Hz, 90-290VDC, Maximum Power 10W | |
Wire Size: | up to 10 AWG (up to 6 mm2 ) | |
Terminals Pitch 7.5 mm, three pins | ||
Auxiliary Power Supply (module) | ||
Withstanding Insulation: | 4kV AC @ 1mn | |
AC/DC Power Supply: | L/+, N/- and GND | |
Rated input: | 50-290VAC 50/60 Hz, 40-290VDC, Maximum Power 20W | |
Low DC/DC Power Supply (module option): | (+), (-) and GND | |
12/24 VDC Option: | Rated input 9.6-35 VDC, Maximum Power 20W | |
Wire Size: | up to 10 AWG (up to 6 mm2 ) | |
Terminals Pitch 7.5 mm, three pins | ||
Input Ratings | AC Voltage Inputs: V1, V2, V3, VN | |
PM180-N1 model | ||
Measuring range: | 57/100 – 400/690 VAC PM180-N1 to N3 model only | |
Direct input and input via PT (up to 576VAC line-to-line, up to 335VAC line-to-neutral) | ||
Input Impedance: | > 1 MW | |
Burden for 400V: | < 0.2 VA | |
Burden for 277V: | < 0.1 VA | |
Burden for 120V: | < 0.02 VA | |
PM180 model | ||
Measuring range: | 57/100 – 277/480 VAC | |
Direct input and input via PT (up to 576VAC line-to-line, up to 335VAC line-to-neutral) | ||
Burden for 277V: | < 0.76 VA | |
Burden for 120V: | < 0.144 VA | |
Overvoltage Withstand: | 1000VAC continuous, 2500VAC for 1 second | |
Galvanic Isolation, withstanding insulation: | 4kV AC @ 1mn | |
Wire Size: | up to 10 AWG (up to 6 mm2 ) | |
Terminals Pitch | 7.5 mm | |
AC/DC Voltage Input: V4, Vref | ||
Operating Range: | 400VAC | |
Direct input and input via PT (up to 480VAC) or Battery input | ||
Input Impedance: | > 10 MW | |
Burden for 400V: | << 0.01 VA | |
Burden for 120V: | << 0.01 VA | |
Overvoltage Withstand: | 1000VAC continuous, 2500VAC for 1 second | |
Resistive Isolation, withstanding Insulation: | 4kV AC @ 1mn | |
Wire Size: | 10 AWG (up to 6 mm2 ) | |
Terminals Pitch: | 7.5 mm | |
AC Transient Voltage Inputs: V1, V2, V3, VN, VG (TRANSIENT RECORDER module) | ||
Measuring range: | up to 2kV AC | |
High impedance input: | 10 MW, withstanding insulation: 4kV AC @ 1mn | |
Wire Size: | up to 10 AWG (up to 6 mm2 ) | |
Terminals Pitch | 7.5 mm | |
AC Current Inputs: Standard: I1, I2, I3, I4 | ||
Input via Internal CT with 5A secondary | ||
Operating range: | maximum continuous 10A/20A RMS (ANSI C12.20 and IEC 62053-22) | |
Nominal measured Current: | In = 5A RMS | |
Fault measured Currents: | up to 50A RMS (10 x In) – without DFR module | |
Burden: | < 0.15 VA | |
Overload Withstand: | 50A RMS continuous, 250A for 1 second | |
Wire Size: | 10 AWG (2.5 to 6 mm2 ) | |
Terminals Pitch: | 9.5 mm | |
Input via Internal CT with 1A secondary | ||
Operating Range: | continuous 4A RMS (ANSI C12.20) or 2A RMS (IEC 62053-22) | |
Nominal measured Current: | In = 1A RMS | |
Fault measured Currents: | up to 10A RMS | |
Burden: | < 0.02 VA | |
Overload Withstand: | 10A RMS continuous, 50A for 1 second | |
Wire Size: | 10 AWG (2.5 to 6 mm2 ) | |
Terminals Pitch: | 9.5 mm | |
Input via SATEC HACS 100A with 40mA secondary | ||
Operating range: | maximum continuous 10A/20A RMS (ANSI C12.20 and IEC 62053-22) | |
Nominal measured Current: | 5A RMS | |
Fault measured Currents: | up to 100A RMS (20 x In) | |
Burden: | < 0.15 VA | |
Overload Withstand: | 100A RMS continuous, 250A for 1 second | |
Wire Size: | 10 AWG (2.5 to 6 mm2 ) | |
Terminals Pitch: | 9.5 mm | |
Fault Current Inputs: Optional DFR Module: I1x, I2x, I3x, I4x – 40 x In maximum measured fault current | ||
Input via SATEC HACS 200A with 40mA secondary | ||
Fault measured Currents: | up to 200A RMS @ In = 5A (40 x In) | |
Burden: | < 0.15 VA | |
Overload Withstand: | 200A RMS continuous, 1000A for 1 second | |
Wire Size: | 10 AWG (2.5 to 6 mm2 ) | |
Terminals Pitch: | 9.5 mm | |
Plug-In I/O Ratings | Digital Inputs – 16 Inputs (up to 3 Modules) | |
Scan time: | 1 ms @ 60Hz, 1.25 ms @ 50Hz. | |
16 optically isolated, dry contact sensing (voltage-free): Internal power supply 24 VDC | ||
Sensitivity: | open @ input resistance >16kOhm, closed @ input resistance <10kOhm | |
Wire Size: | 12 AWG (up to 2.5 mm2 ) | |
Terminals Pitch: | 3.81 mm | |
16 optically isolated, wet contact sensing: | ||
External Power Supply: | 24 VDC | |
Sensitivity: | open @ input resistance >16kOhm, closed @ input resistance <10kOhm | |
Wire Size: | 12 AWG (up to 2.5 mm2 ) | |
Terminals Pitch: | 3.81 mm | |
16 optically isolated, wet contact sensing: | ||
External Power Supply: | 48 VDC | |
Wire Size: | 12 AWG (up to 2.5 mm2 ) | |
Terminals Pitch: | 3.81 mm | |
16 optically isolated, wet contact sensing: | ||
External Power Supply: | 125 VDC | |
Wire Size: | 12 AWG (up to 2.5 mm2 ) | |
Terminals Pitch: | 3.81 mm | |
16 optically isolated, wet contact sensing: | ||
External Power Supply: | 250 VDC | |
Wire Size: | 12 AWG (up to 2.5 mm2 ) | |
Terminals Pitch: | 3.81 mm | |
Relays - 8 Outputs (up to 3 Modules) 8 relays -SPSTForm A | ||
Contact rating: | 8A @ 250V AC, 5A @ 30V DC 0.25A @ 250V DC (sw. Volt.) 5A 24V DC (sw. Cur.) | |
Wire Size: | 12 AWG (up to 2.5 mm2 ) | |
Terminals Pitch: | 3.81 mm | |
Update time: | 1/2 cycle | |
Analog I/O – 4 Inputs, 4 Outputs (up to 3 Modules) | ||
4 Analog Inputs: | ||
Ranges (upon order): | ±1 mA (100% overload) 0-20 mA 4-20 mA 0-1 mA (100% overload) | |
Accuracy: | 0.5% FS | |
Scan time: | 2 cycles | |
Wire Size: | 12 AWG (up to 2.5 mm2 ) | |
Terminals Pitch: | 5 mm | |
4 Analog Outputs: | ||
Ranges (upon order): | ±1 mA, maximum load 10 kW (100% overload) 0-20 mA, maximum load 510 W 4-20 mA, maximum load 510 W 0-1 mA, maximum load 10 k W (100% overload) | |
Accuracy: | 0.5% FS | |
Update time: | 2 cycles | |
Wire Size: | 12 AWG (up to 2.5 mm2 ) | |
Terminals Pitch: | 5 mm | |
Communication Ports | COM1 (CPU) Serial EIA RS-232/485 optically isolated port | |
Withstanding Insulation: | 4kV AC @ 1 mn | |
Connector Type: | removable, captured-wire, 4 terminals. | |
Wire Size: | up to 12 AWG (up to 2.5 mm2 ). | |
Baud Rate: | up to 115,200 bps. | |
Supported Protocols: | MODBUS RTU/ASCII, DNP 3.0 | |
COM2 (Communication Module) Serial EIA RS-422/RS-485 optically isolated port | ||
Withstanding Insulation: | 4kV AC @ 1 mn | |
Connector type: | removable, captured-wire, 5 terminals. | |
Wire Size: | up to 12 AWG (up to 2.5 mm2 ). | |
Baud Rate: | up to 115,200 bps. | |
Supported Protocols: | MODBUS RTU/ASCII, DNP 3.0 | |
COM3 (Display Communication port) Serial EIA RS-485 optically isolated port for the RDM. | ||
Withstanding Insulation: | 2.5kV AC @ 1 mn | |
Connector Type: | DB15 | |
Baud Rate: | up to 115,200 bps. | |
Supported Protocols: | MODBUS RTU/ASCII, DNP 3.0 | |
USB Port (CPU) Isolated USB 1.1 port. | ||
Withstanding Insulation: | 4kV AC @ 1 mn | |
Connector Type A male, standard USB cable, max. Length 2 meters | ||
Supported protocols: | MODBUS RTU | |
Ethernet Port (CPU) Transformer-isolated 10/100Base-T port | ||
Withstanding Insulation: | 4kV AC @ 1 mn | |
Connector Type: | RJ45 modular | |
Supported Protocols: | MODBUS TCP (Port 502), DNP 3.0/TCP (Port 20000), IEC 61850 | |
Number of simultaneous connections (sockets): | 5 | |
ETH2 - 10/100 TX- 100 FX (Communication Module) Transformer-isolated 10/100Base-T port | ||
Connector Type TX port: | RJ45 modular | |
Optical-isolated 100Base FX | ||
Connector Type FX port: | SC | |
Supported Protocols: | MODBUS TCP (Port 502), DNP 3.0/TCP (Port 20000), IEC 61850 | |
Number of simultaneous connections (sockets): | 5 | |
COM5 - CELLULAR (Communication Module) 2G/3G CELLULAR MODEM | ||
Withstanding Insulation: | 2.5kV AC @ 1 mn | |
Connector type: | SMA | |
Supported Protocols: | MODBUS TCP (Port 502), DNP 3.0/TCP (Port 20000) | |
Infrared (RGM180) Optional optical IEC/ANSI head | ||
Baud Rate: | up to 115,200 bps. | |
Supported Protocols: | MODBUS RTU/ASCII, DNP 3.0 | |
Real-time Clock | Accuracy: maximum error 5 seconds per month @ 25°C | |
IRIG-B | Recommended cable: | 51Ohm low loss - RG58A/U (Belden 8219 or equivalent), TNC connector |
Recommended GPS time code generator: | Masterclock GPS-200A | |
CPU Board (PM180 – N3 version) Optically isolated IRIG-B port | ||
Withstanding Insulation: | 4kV AC @ 1 mn | |
Time code signal: | non-modulated (pulse-width coded). | |
Level: | unbalanced 5V. | |
Connector type: | removable, captured-wire, 4 terminals | |
Communication Module Optically isolated IRIG-B port | ||
Withstanding Insulation: | 4kV AC @ 1 mn | |
Time code signal: | non-modulated (pulse-width coded). | |
Level: | unbalanced 5V. | |
Connector Type: | BNC. | |
Log Memory | Standard onboard memory: | 250 Mbytes. |
Remote Display Module | RDM180 (PM180-D model) | |
Display: | high-brightness seven-segment digital LEDs, two 4-digit windows and one 6-digit windows | |
Keypad: | 6 push buttons | |
Communication: | EIA RS-485 port with 12V supply voltage | |
Connector Type: | DB15 | |
Wires Size: | up to 12 AWG (up to 2.5 mm2 ) | |
Distance: | 3m cable (10 feet) up to 500m (2000 feet) with external 12VDC power supply | |
RDM312 (PM180-M model) | ||
Display: | high-brightness seven-segment digital LEDs, nine 4-digit windows and three 6-digit windows | |
Keypad: | 7 push buttons | |
Communication: | EIA RS-485 port with 12V supply voltage | |
Connector Type: | DB15 | |
Wires Size: | up to 12 AWG (up to 2.5 mm2 ) | |
Distance: | up to 500m (2000 feet) with external 12VDC power supply | |
RGM180 (PM180-G) | ||
5.7 Inch Touch-Panel LCD graphic TFT display | ||
Resolution: | 320 x 240 | |
Operating temperature: | -20°C - +70 °C | |
Communication: | EIA RS-485 port with 12V supply voltage | |
Connector Type: | DB15 | |
Wires Size: | up to 12 AWG (up to 2.5 mm2 ) | |
Distance: | up to 500m (2000 feet) | |
10/100Base T ETHERNET port with 12 V supply voltage and PoE (Power over ETHERNET) | ||
Connector Type: | RJ-45 and DB15 (for 12VDC external Power Supply connection) |
-
Nhằm giúp cho trải nghiệm khách hàng luôn được tối ưu, Patek luôn chú ý đến từng nhu cầu dù nhỏ của khách hàng để hoàn thiện dịch vụ. Cung cấp đủ thông tin, tài liệu kỹ thuật về sản phẩm với ngôn ngữ Anh - Việt theo yêu cầu giúp cho khách hàng có cơ sở để quyết định nhanh chóng trong việc lựa chọn sản phẩm với độ tin cậy, đáp ứng cao cho nhu cầu, ứng dụng.
-
Ngoài ra nếu bạn đăng ký tài khoản trên website, hoặc trở thành khách mua hàng của chúng tôi thì bạn cũng có thể tiếp cận thêm nhiều nguồn tài liệu quý giá và hữu ích dành riêng.
- Trong trường hợp chưa tìm thấy tài liệu đáp ứng nhu cầu, quý khách có thể gửi yêu cầu cụ thể trong phần Hỗ trợ
-
Nếu bạn đã đăng nhập tài khoản vui lòng nhấp vào đây để đi đến phần hỗ trợ tài liệu dành riêng.
I. Tài liệu Tiếng Anh:
II. Tài liệu Tiếng Việt:
Đang cập nhật...