The EM133 can serve any application from residential energy metering, through industrial energy and harmonic analysis through utility comprehensive substation automation. It provides multifunctional 3‑phase power metering, revenue metering and basic power quality information. The EM133 features an internal real time clock (RTC), battery backup and onboard non-volatile memory for event and data logging. The device includes 16 set points and 4 counters that operate the built in 2 DI/ 1RO or the various analog and digital I/O add-ons.

 

The EM133 offers a wide range of network configurations and versatile voltage and current connections: 57 to 400V AC, up to 100A direct current measurement, connection of standard CTs (1A, 5A) and a wide range of remote HACS - High Accuracy Current Sensors (split or solid cores).

Tiêu đề
Hotline hỗ trợ: +84 98 70 35 546
|
Số lượng
Báo giá nhanh

Environmental Conditions

Operational ambient temperature limit range:

–25°C to +60°C

 

Specified ambient temperature range:

Specified ambient temperature range:

 

Long-term damp heat withstand according to IEC 68-2-3

 

Transport and storage temperature range:

–30°C to +85 °C

 

IEC 60068-2-6, AS 60068-2-6 [18]: Vibration

 

Frequency range:

10Hz to 150Hz

 

Vibration time (each axis):

 75 min

 

Sweep rate:

1 oct/min

 

Max Vibration level:

10 m/s2 (1g), f > 60Hz

 

IEC 60068-2-27, AS 60068-2-27 [19]: Shock

 

Shock level:

30 g

 

Time duration:

18 ms

 

Shape:

Half sine

 

Number of shocks:

18

Construction

Case enclosure:

Reinforced Polycarbonate

 

Packaging case:

Carton and Stratocell® (Polyethylene Foam) brackets

 

Labels:

Polyester film (UL94-V0)

Three Phase Power Supply – EM133-SE (Y &D)

Indirect Connection or Direct Connection using HACS

 

Rated input from 1, 2 or 3 phases:

3 x 120/207-277/480 VAC 50/60Hz

 

Burden 2VA per phase

 

Rated input from 1, 2 or 3 phases:

3 x 120/207-230/400 VAC 50/60Hz

 

Isolation:

Input to ground: 4000V AC

Auxiliary Power Supply – EM132-133

Rated input:

40-300VAC 50/60Hz, 40-300VDC, Burden 5VA

 

Frequency range operation 25-400 Hz

 

Isolation:

Input to ground: 4000V AC

Input Ratings

Voltage Inputs – Installation category

III Model with 3 Phase Power Supply – EM133-SE (Y &D)

 

Operating range:

120/207V to 277/480VAC for 1A/5A/RS5 models

 

Operating range:

120/207V to 230/400VAC for HACS models

 

Frequency range measurement 50-60 Hz

 

Burden for 277V:

< 1.5 VA

 

Burden for 120V:

< 2 VA

 

Model with Aux. Power Supply – EM132-133

 

Operating range:

up to 400/690 VAC

 

Measurement range:

direct input and input via PT up to 828VAC line-toline, up to 480VAC line-to-neutral

 

Frequency range measurement 25-400 Hz

 

Burden for 400V:

< 0.4 VA

 

Burden for 120V:

< 0.04 VA

 

Over-voltage withstands:

1000 VAC continuous, 2000 VAC for 1 second

 

Input impedance:

1000 kW

 

Current Inputs (via CT) – Installation category III

 

Galvanic isolation:

4000V AC

 

5A secondary (standard)

 

Current rating:

5A RMS

 

Maximum continuous current:

10A RMS

 

Frequency range measurement 25-400 Hz

 

Burden:

< 0.2 VA @ In=5A

 

Overload withstanding:

15A RMS continuous, 300A RMS for 1 second

 

1A secondary (1A option)

 

Current rating:

1A RMS

 

Maximum continuous current:

2A RMS

 

Frequency range measurement 25-400 Hz

 

Burden:

< 0.02 VA @ In=1A

 

Overload withstanding:

3A RMS continuous, 80A RMS for 1 second

 

50A direct (100A option)

 

Current rating:

50A RMS

 

Maximum continuous current:

100A RMS @ 55°C ambient temperature

 

Maximum continuous current:

60A RMS @ 60°C ambient temperature

 

Frequency range measurement 25-400 Hz up to 50A

 

Burden:

< 0.02 VA @ In=50A

 

Overload withstanding:

100A RMS continuous @ 55°C, 2500A RMS for 1 second

 

40mA secondary – with HACS (external CT option)

 

External CT Operating range:

continuous 100-1200A RMS

 

Frequency range measurement 50-60 Hz

 

5mA secondary – with external CT (RS5 option)

 

Operating range:

continuous 10A RMS

 

Frequency range measurement 50-60 Hz

 

Burden:

< 0.2 VA @ In=5A

 

Overload withstanding:

15A RMS continuous, 300A RMS for 1 second

 

Sampling Rate measurement

128 samples per cycle

Relay Outputs

Solid State relay standard

1 relay rated at 0.15A/24V AC/DC, 1 contact (SPST Form A)

 

Galvanic isolation:

4000V AC 1 min

 

Operate time:

1 ms max.

 

Release time:

0.25 ms max

 

Update time:

1 cycle

 

Electromechanical relay - DRY contact, option (4DI/2DO and 12DI/4DO Optional modules)

 

2 or 4 relays rated at 5A/250V AC; 5A/30V DC, 1 contact (SPST Form A)

Galvanic isolation:

 

Between contacts and coil:

3000V AC 1 min

 

Between open contacts:

750V AC

 

Operate time:

10 ms max

 

Release time:

5 ms max.

 

Update time:

1 cycle

 

Solid State relay option (4DI/2DO Optional module)

2 relays rated at 0.15A/250V AC/DC, 1 contact (SPST Form A)

 

Galvanic isolation:

3750V AC 1 min

 

Operate time:

1 ms max.

 

Release time:

0.25 ms max

 

Update time:

1 cycle

 

Connector type:

removable, 4 pins.

Digital Inputs

Digital Input (standard)

1 Digital Inputs Dry Contacts, internally wetted @ 5VDC

 

Sensitivity:

Open @ input resistance >100 kW, Closed @ Input resistance < 100 W

 

Galvanic isolation:

4000V AC 1 min

 

Internal power supply:

5VDC

 

Scan time:

1 ms

 

Digital Input (option)

4 Digital Inputs Dry Contacts, internally wetted @ 24VDC (4DI/2DO Optional module)

 

Sensitivity:

Open @ input resistance >100 kW, Closed @ Input resistance < 100 W

 

Galvanic isolation:

3750V AC 1 min

 

Internal power supply:

24V DC

 

Scan time:

1 ms

 

Connector type:

removable, 5 pins

 

8 Digital Inputs Dry Contacts, internally wetted @ 24VDC (8DI Optional module)

 

Sensitivity:

Open @ input resistance >100 kW, Closed @ Input resistance < 100 W

 

Galvanic isolation:

3750V AC 1 min

 

Internal power supply:

24V DC

 

Scan time:

1 ms

 

Connectors type:

removable, 4 and 5 pins

 

12 Digital Inputs Dry Contacts (12DI/4DO Optional module)

 

Galvanic isolation:

2500V AC 1 min

 

Scan time:

1 ms

 

Connector type:

removable, 5 pins.

 

Internally/externally wetted @ 24VDC - option 1/2:

Wet contact sensing: Open > 16kW, Closed < 10kW

 

Externally wetted @ 120VDC - option 3:

Wet contact sensing option 1: Open > 160kW, Closed

 

Externally wetted @ 220VDC - option 4:

Wet contact sensing option 1: Open >320kW, Closed <100kW

Optional Analog Outputs

4 Analog Outputs optically isolated (AO Optional module)

Ranges (upon order):

±1 mA, maximum load 5 kW (100% overload)

0-20 mA, maximum load 510 W 4-20 mA, maximum load 510 W 0-1 mA, maximum load 5 k W (100% overload)

Isolation:

2500V AC 1 min

Power supply:

internal

Accuracy:

0.5% FS

Update time:

1 cycle

Connector type:

removable, 5 pins

Communication Ports

COM1 (standard)

RS-485 optically isolated port

 

Isolation:

3000V AC 1 min

 

Baud rate:

up to 115.2 kbps.

 

Protocols:

Modbus RTU, DNP3, SATEC ASCII and IEC 60870-5-101

 

Connector type:

removable, 3 pins

 

COM2 option

Ethernet Port(Optional module)

Transformer-isolated 10/100BaseT Ethernet port

 

Protocols:

MODBUS/TCP (Port 502), DNP3/TCP (Port 20000),

IEC 60870-5-104

 

Number of simultaneous connections:

4 (2 MODBUS/TCP + 2 DNP3/TCP).

 

Connector type:

RJ45 modular.

 

PROFIBUS DP (IEC 61158) (Optional module)

RS-485 optically isolated PROFIBUS interface.

 

Connector type:

removable, 5 pins.

 

Baud rate:

9600 bit/s – 12 Mb/s (auto detection).

32 bytes input, 32 bytes output.

 

Protocols:

PROFIBUS

 

CANopen (Optional module)

RS-485 optically isolated CANopen interface.

 

Connector type:

removable, 5 pins.

 

Protocols:

CANopen

 

RS-232/422-485 Port (Optional module)

RS-232 or RS-422/485 optically isolated port

 

Isolation:

3000V AC 1 min

 

Baud rate:

up to 115.2 kbps.

 

Protocols:

MODBUS RTU, DNP3, and SATEC ASCII

 

Connector type:

removable, 5 pins for RS-422/485 and DB9 for RS-232.

 

COM3 (standard)

Infra-Red COM port

Real-time Clock

Standard Meter Clock

Crystal Clock Accuracy:

typical error 13.15 sec per month (2.63 minutes per year) @ 25°C (±5ppm)

Typical clock retention time:

15 months

TOU Module Meter Clock (option)

Accuracy:

typical error 7 seconds per month @ 25°C (±2.5ppm)

Typical clock retention time:

36 months

  • Nhằm giúp cho trải nghiệm khách hàng luôn được tối ưu, Patek luôn chú ý đến từng nhu cầu dù nhỏ của khách hàng để hoàn thiện dịch vụ. Cung cấp đủ thông tin, tài liệu kỹ thuật về sản phẩm với ngôn ngữ Anh - Việt theo yêu cầu giúp cho khách hàng có cơ sở để quyết định nhanh chóng trong việc lựa chọn sản phẩm với độ tin cậy, đáp ứng cao cho nhu cầu, ứng dụng.

  • Ngoài ra nếu bạn đăng ký tài khoản trên website, hoặc trở thành khách mua hàng của chúng tôi thì bạn cũng có thể tiếp cận thêm nhiều nguồn tài liệu quý giá và hữu ích dành riêng.

  • Trong trường hợp chưa tìm thấy tài liệu đáp ứng nhu cầu, quý khách có thể gửi yêu cầu cụ thể trong phần Hỗ trợ
  • Nếu bạn đã đăng nhập tài khoản vui lòng nhấp vào đây để đi đến phần hỗ trợ tài liệu dành riêng.