Patek

pt_ELECTRICAL_2 valiu_2017 PONOVO GLOBECORE CA

High Voltage/Current Testing KEP-HVTS 70/50

Email

Product: High Voltage/Current Testing
Model: KEP-HVTS 70/50
Manufacturer: Kharkovenergopribor
Description

Technical Specifications

Parameter Value
Supply voltage single-phase AC current, V 220 ± 22
Frequency, Hz 50 ± 2
Highest power consumption, kW, max 3
Highest output voltage, kV:
- AC 50
- DC 70
Highest output current, mA:
- on an AC voltage 45
- on the DC voltage 20
Relative error voltage, %:
- AC voltage from 3 kV to 50 kV

± 3

- DC voltage of 3 kV to 70 kV ± 3
Relative error of current measuring, %:
- AC current of 1,0 mA to 45,0 mA ± 3
- DC current of 0,1 mA to 20 mA ± 3
Modes manual / auto
Rate of voltage increase, % / s 1-9
Maximum voltage threshold, kV:
- on an AC voltage 52
- on the DC voltage 72
Treshold current ofr the power supply, A, max 10
Programmable timer, min, max 10
Archiving of test results, quantity 32
Remote communication with the PC over Bluetooth, m, max 10
Сontrol Unit dimensions, mm, max 266×240×354
Сontrol Unit Weight, kg, max 14
BVIEG (HVU-G) dimensions, mm, max 355×325×350
BVIEG (HVU-G) Weight, kg, max 23
Lifespan, years, average 10

Operating Conditions

The device is designed for an indoors operation under the following conditions:

Condition Value
Air temperature, °С from -10 to +40
Relative humidity, %, up to 98 at +25 °С
Atmospheric pressure, kPa (mm hg) 84,0 – 106,7 (630 – 800)

Package Contents

Component Quantity
Control Unit 1
High Voltage Unit (BVIEG) 1
Power cable (4 m, cross section 3x0,75 mm2)
1
Ground wire (4 m, cross-section 4 mm2) 2
High-Voltage wire (4 m), Utest ≤ 25kV 1
Control Unit cable connection (3 m) 2
Software CD 1
Fuse VP2 -1, 1.0 A 2
Fuse VP3 -1, 10.0 A 2
 
Documentation
Manual 1
Passport 1
Metrological certification of GP "Kharkivstandartmetrologiya" Optional