Patek

pt_ELECTRICAL_2 valiu_2017 PONOVO GLOBECORE CA

Leak Detection Tru pointe

Email

Product: Leak Detection
Model: Tru pointe
Manufacturer: Bacharach
Download documents:

Data Sheet
Manual

Description

Sensing Element:

  • Type: Plug-in, Patented, Heated Diode — U.S. Patent No. 5,932,176
  • Life Expectancy: 150 hours or 1 year of normal use

Refrigerants Detected:All CFC, HCFC and HFC refrigerants including: R-12, R-22, R-123, R-134a and blends R-404A, R-408A, R-409A and R-410A (i.e., any refrigerant containing Chlorine, Fluorine or Bromine gas)

Alarm Sensitivity: 0.1 oz/year of R134a (hardest to detect refrigerant)

Alarm Types: Variable-intensity audible and visual

Power Source: Two ‘D’ disposable alkaline batteries

Warm-up Time: 10 seconds

Response Time: Instantaneous

Battery Life: 8 to 13 hours continuous operation, dependent on sensitivity mode

Probe: 14" (356mm) flexible

Size: 2" W x 9.38" L x 2.5" H (50.8 x 238.3 x 63.5 mm)

Weight: 1.16 lbs. (0.53 kg) w/ batteries

Agency Approvals: UL listed in accordance with SAE J1627

CE-Mark: Independently tested

Warranty: One year, including sensor