Patek

2018 BANNER pt_ELECTRICAL_2 valiu_2017 PONOVO GLOBECORE CA

Combustion Analyzers PCA-3

Email

Product: Combustion Analyzers
Model: PCA-3
Manufacturer: Bacharach
Download documents:

Data Sheet

Description

Specifications:

Measurement Ranges North American Version
Primary/Ambient Air Temperature -4° to 999°F
Stack Temperature -4° to 2192°F
Oxygen 0 to 20.9%
Carbon Monoxide (H2 Compensated) 0 to 4,000 ppm
Carbon Monoxide, (High Range) 4,001 to 20,000 ppm
Nitric Oxide 0 to 3,000 ppm
Nitrogen Dioxide 0 to 500 ppm
Sulfur Dioxide 0 to 5,000 ppm
Pressure/Draft -72 to +72 inwc
Calculated Ranges Combustion Efficiency 0.1 to 100%
Excess Air 1.0 to 250%
Carbon Dioxide (Dry Basis) 0 to Fuel Dependent Maximum
NOx (NO + NO2) 0 to 3,500 ppm
NOx referenced to % O2 0 to 9,999 ppm
CO referenced to % O2 0 to 9,999 ppm
NO referenced to % O2 0 to 9,999 ppm
NO2 referenced to % O2 0 to 9,999 ppm
SO2 referenced to % O2 0 to 9,999 ppm
Accuracy Oxygen ± 0.3% O2 (Flue Gas)
Stack or Flue Gas Temperature ± 4°F between 32 and 255°F
(± 2°C between 0 and 124°C)
± 6°F between 256 and 480°F
(± 3°C between 125 and 249°C)
± 8°F between 481 and 752°F
(± 4°C between 250 and 400°C)
Primary-air/Ambient Temperature ± 2°F between 32 and 212°F
(± 1°C between 0 and 100°C)
Pressure/Draft ± 2% Reading or 0.02 inwc -1 to 10 inwc
± 3% of Reading between ± -40 and ± 40 inwc
CO ± 5% of Reading or ± 10 ppm in the range of 0-2000 ppm CO
± 10% of Reading between 2001 to 4,000 ppm
NO ± 5% of Reading or ± 5 ppm whichever is greater between 0 to 2000 ppm NO
NO2 ± 5% of Reading or ± 5 ppm whichever is greater between 0-500 ppm NO2
SO2 ± 5% of Reading or ± 10 ppm whichever is greater between 0-2000 ppm SO2