Specifications

Dimensions 8.0" x 5.5" x 4.61" (20.32 cm x 13.97 cm x 11.71 cm)
Housing Durable Aluminum Enclosure - Suitable for Class 1, Div. 1 & 2, Groups B, C, D
Front Panel 5 Indicator Lights: Alarm 1, Alarm 2, Fail, In Calibration, and RS-485
User Interface 64 x 128 Pixel LCD Graphic Display for Gas Readings, 30 Minute Trend, Bar Graphing, Engineering Units and Backlight
Operating Temperature Range -40°F to 140°F (-40°C to 60°C)
Ambient Humidity Range 5% - 90% RH Non-Condensing
Security Mode Lock Out Critical Parameters
4-20 mA Output Signal 3-wire, 4-20 mA. Max Loop Resistance is 750 Ω (@24 VDC)
Alarm Relays 3 Configurable Form C (SPDT) Relays rated for 5 amp at 30 VDC or 240 ~ VAC RESISTIVE. | Relay 1 and Relay 2 Level Alarms are
configurable for HIGH or LOW Trip, for Normally Energized (Failsafe) or Normally De-Energized and for Latching or Non-Latching.
Relay 3 is always Normally Energized for Failsafe Operation so any loss of power to the GDX-350 will be indicated as a "FAULT" condition.
Communications RS-485, Modbus®
Power 10 - 30 VDC, 250 mA (@ 24 VDC)
Power Safety Mode Fully automatic system reset. All program parameters are retained.
Approvals CSA: Division 1 & 2, Class 1: Groups B, C, D (excludes NH3